Bladder tank foam system

Bladder tank foam system

  • 料號:CD-G
商品簡述

This product uses the water pressure of the fire hose to press the bag in the tank so that the foam concentrate in the bag can be mixed with the water in the fire hose in the mixer into the 3% or 6% water/foam mixture according to the preset volume. The mixture will then flow through various foam generators in the protected area and generate foam to extinguish the fire. In addition, the mixture ratio stays the same whether the water pressure in the main hose rises or drops.

Bladder tank foam system

This product uses the water pressure of the fire hose to press the bag in the tank so that the foam concentrate in the bag can be mixed with the water in the fire hose in the mixer into the 3% or 6% water/foam mixture according to the preset volume. The mixture will then flow through various foam generators in the protected area and generate foam to extinguish the fire. In addition, the mixture ratio stays the same whether the water pressure in the main hose rises or drops.

  1.         This product uses the water pressure of the fire hose to press the bag in the tank so that the foam concentrate in the bag can be mixed with the water in the fire hose in the mixer into the 3% or 6% water/foam mixture according to the preset volume. The mixture will then flow through various foam generators in the protected area and generate foam to extinguish the fire. In addition, the mixture ratio stays the same whether the water pressure in the main hose rises or drops.
  2.         The tank contains an acid/alkali resistance bag (foam bag) of the same volume to store the foam concentrate. The foam concentrate does not directly mix with the water; instead, a certain volume of the foam concentrate is squeezed out by the water pressure.
  3.         In general, one mixer can only be installed in one tank. However, it can be customized based on customer demand to two bags in one tank with different mixture ratios. The manual valve along the system pipes can be modified into an electrical or aerodynamic valve. It can be operated by the system remotely without having to send personnel to the scene.
  4.         The selection of a 3% or 6% mixture is based on the nature of the flammable goods in the protected area as follows:

•   3% - suitable for nonpolar flammable solvent fires

•   6% - suitable for polar flammable solvent fires

  1.         This product is suitable for dangerous areas where fires can break out easily: oil tank areas, chemical plants, solvent warehouses, oil filling plants, and underground parking lots.
  2.         Apart from the listed specifications and volume in the table, the scale and size can be customized based on customer demand (please refer to the sketch of the system).

extinguisher manufacturers


Mixer Size

Size

L

A

B

C

D

E

H

W

Flange specifications

8”

693

300

300

100

2-1/2”

152

122

93

Specifications:

□ ANSI 150#

□ JIS 10K

□ Other ________

Type: □ RF □ FF

6”

673

300

300

88

2”

140

96

73

4”

673

300

300

76

2”

88

72

73

2”

656

300

300

76

1-1/4”

76

62

56

2-1/2”

656

300

300

76

1-1/4”

76

52

56

Mixer Suitable Flow range

Size

Flow range gpm (lpm)

Pressure loss gpm (lpm)

Minimum

Maximum

Minimum

Maximum

8”

400(1515)

5000(18921)

0.1(0.7)

11(76)

6”

250(947)

3000(11357)

0.2(1.4)

12(83)

4”

150(568)

1200(4543)

0.3(2.1)

11(76)

2”

70(265)

450(1704)

0.3(2.1)

11(76)

2-1/2”

35(133)

230(871)

0.3(2.1)

7(49)

Volume unit conversion: 1gal (gallon) = 3.7852L (liter)

Foam concentration tank specifications

Volume (gal)

Model

Size

Base bolts

Total weight (kg)

50

CD-50G

Please contact our company and we will provide you with a more detailed size list

1/2”X 250L

422

100

CD-100G

1/2”X 250L

539

150

CD-150G

1/2”X 250L

610

200

CD-200G

1/2”X 250L

662

300

CD-300G

1/2”X 250L

736

400

CD-400G

1/2”X 300L

962

500

CD-500G

1/2”X 300L

1579

600

CD-600G

1/2”X 300L

1719

700

CD-700G

1/2”X 300L

1846

800

CD-800G

1/2”X 300L

1902

900

CD-900G

1/2”X 300L

2005

1000

CD-1000G

5/8”X 300L

2155

1100

CD-1100G

5/8”X 300L

2250

1200

CD-1200G

5/8”X 300L

2616

1300

CD-1300G

5/8”X 300L

2785

1400

CD-1400G

5/8”X 300L

3030

1500

CD-1500G

5/8”X 300L

3207

1700

CD-1700G

5/8”X 300L

3560

2000

CD-2000G

7/8”X 300L

4606

2500

CD-2500G

7/8”X 300L

5247

3000

CD-3000G

7/8”X 300L

5510

3300

CD-3300G

7/8”X 300L

6930

 

Horizontal diaphragm pressure equalizing bladder tank foam proportioning system

Model

CD- G

Designed pressure

150225psi10.515.8kg/cm2

Operating pressure

100175psi712.3kg/cm2

Designed temperature

140℉60℃

Operating temperature

59104℉1540℃

Mixture ratio specifications
and size description

1. Inlet pressure: based on the system demand
2. Water/foam mixture ratio: 3% (nonpolar solvent fire), 6% (polar solvent)
3. Ratio precision: ±0.3%

Material

Tank body - JIS SS400/SB410 or ASTM A285-C or SUS304
Stand - JIS SS400/SB410 or ASTM A283-C or SUS304
Foam bag -
a. Single layer neoprene (chloroprene rubber)
b. Internal and external layers of neoprene (chloroprene rubber), middle layer is 840-denier nylon cloth.
Note: The materials for both specifications above are optional and can be customized based on customer demand.
Flange - ASTM A105 ANSI 150# RF/FF or JIS 10K or SUS304
Pipe - ASTM A106 or SUS304

Related Products